Fuses
250V 25A 2x9/16 RK5 TD FU
Service entrance equipment; Transformers; CSA certified to standard C22.2 no. 248.12; Time-delay; Current-limiting; Optional solid state SmartSpot blown fuse indicator; General-purpose equipment; High-grade silica filler ensures fast arc quenching and high current limitation; Easy-to-read label for quick brand recognition and replacement; Current-limiting for low peak let-thru current; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Mains; Fiberglass body provides dimensional stability in harsh industrial settings; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Branch circuits; Motor circuits; Feeders; Metal-embossed date and catalog number for traceability and lasting identification; UL listed to standard 248-12 File E2137; AC & DC rated; DC listed to UL standard 248 TRS only
690V CP 14X51 GG 4A S/I FS
Approved by Lloyd’s Register of Shipping and Bureau Veritas; Striker version available for remote indication of fuse operation; Full range protection; IEC 60269-1 & -2; Reduced size; Safest and most reliable protection system
250V 5A RK1 TD FUSE
Solid state SmartSpot visual blown fuse indicator; All general-purpose circuits; 600VAC & 600VDC dual rated; Reduced inventory by taking the place of class RK5, K, and H fuses; Fiberglass body provides dimensional stability in harsh industrial settings; Transformers; CSA certified to standard C22.2 No. 248.12; 300kA interrupting rating – self-certified, UL witnessed tests; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; DC listed to UL standard 248; UL listed to standard 248-12 File E2137; Disconnects; Extremely current-limiting for low peak let-thru current; Time-delay for motor starting and transformer inrush currents without nuisance opening; Branch circuit protection; High-visibility orange label gives instant brand recognition; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Motors; Control panels; Metal-embossed date and catalog number for easier traceability and lasting identification; Recommended for Arc Flash energy reduction; Safety switches
1000V 30A SEMICOND FUSE
Low I2t minimizes damage to protected components on short circuit; Wide range of ampere ratings; UL recognized component File E60314; AC: UL guide no. JFHR2 (35-600A); Controlled arc voltage reduces stress to circuit components during fuse clearing; DC: self-certified
690V CP 14X51 AM 25A S/I FS
IEC 60269-1 & -2; Striker version available for remote indication of fuse operation; Approved by Lloyd’s Register of Shipping and Bureau Veritas; Safest and most reliable protection system; Reduced size
250V 1-1/4A RK1 TD FUSE
Disconnects; 300kA interrupting rating – self-certified, UL witnessed tests; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Reduced inventory by taking the place of class RK5, K, and H fuses; High-visibility orange label gives instant brand recognition; Fiberglass body provides dimensional stability in harsh industrial settings; Solid state SmartSpot visual blown fuse indicator; All general-purpose circuits; 600VAC & 600VDC dual rated; Time-delay for motor starting and transformer inrush currents without nuisance opening; UL listed to standard 248-12 File E2137; Control panels; DC listed to UL standard 248; Safety switches; Recommended for Arc Flash energy reduction; Branch circuit protection; Motors; CSA certified to standard C22.2 No. 248.12; Transformers; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”
250V 1-1/8A RK1 TD FUSE
600VAC & 600VDC dual rated; Control panels; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Solid state SmartSpot visual blown fuse indicator; Metal-embossed date and catalog number for easier traceability and lasting identification; Safety switches; DC listed to UL standard 248; Fiberglass body provides dimensional stability in harsh industrial settings; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Branch circuit protection; Disconnects; Recommended for Arc Flash energy reduction; Time-delay for motor starting and transformer inrush currents without nuisance opening; Motors; UL listed to standard 248-12 File E2137; 300kA interrupting rating – self-certified, UL witnessed tests; High-visibility orange label gives instant brand recognition; Extremely current-limiting for low peak let-thru current; Reduced inventory by taking the place of class RK5, K, and H fuses; CSA certified to standard C22.2 No. 248.12; Transformers; All general-purpose circuits
250V 1-4/10A RK1 TD FUSE E
Reduced inventory by taking the place of class RK5, K, and H fuses; Control panels; 600VAC & 600VDC dual rated; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High-visibility orange label gives instant brand recognition; Metal-embossed date and catalog number for easier traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests; Solid state SmartSpot visual blown fuse indicator; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Fiberglass body provides dimensional stability in harsh industrial settings; Time-delay for motor starting and transformer inrush currents without nuisance opening; UL listed to standard 248-12 File E2137; DC listed to UL standard 248; Transformers; All general-purpose circuits; Branch circuit protection; Safety switches; CSA certified to standard C22.2 No. 248.12; Recommended for Arc Flash energy reduction; Extremely current-limiting for low peak let-thru current; Disconnects; Motors
250V 17-1/2A RK1 TD FUSE
CSA certified to standard C22.2 No. 248.12; Fiberglass body provides dimensional stability in harsh industrial settings; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Metal-embossed date and catalog number for easier traceability and lasting identification; Recommended for Arc Flash energy reduction; Control panels; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Solid state SmartSpot visual blown fuse indicator; All general-purpose circuits; Time-delay for motor starting and transformer inrush currents without nuisance opening; High-visibility orange label gives instant brand recognition; DC listed to UL standard 248; Safety switches; 300kA interrupting rating – self-certified, UL witnessed tests; Transformers; Reduced inventory by taking the place of class RK5, K, and H fuses; Motors; Extremely current-limiting for low peak let-thru current; Branch circuit protection; UL listed to standard 248-12 File E2137; 600VAC & 600VDC dual rated; Disconnects
250V 1A RK1 TD FUSE
UL listed to standard 248-12 File E2137; Transformers; Control panels; Recommended for Arc Flash energy reduction; Solid state SmartSpot visual blown fuse indicator; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Disconnects; DC listed to UL standard 248; Reduced inventory by taking the place of class RK5, K, and H fuses; Safety switches; CSA certified to standard C22.2 No. 248.12; High-visibility orange label gives instant brand recognition; All general-purpose circuits; Metal-embossed date and catalog number for easier traceability and lasting identification; Motors; Branch circuit protection; 600VAC & 600VDC dual rated; Fiberglass body provides dimensional stability in harsh industrial settings; 300kA interrupting rating – self-certified, UL witnessed tests; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”