Fuses
ZB T1 100kA 240/120V SP N4X
UL96A Lightning Protection; CSA C22.2, Type 1 SPD; Type 1 SPD for service entrance and facility-wide protection; ANSI/IEEE C62.41.1, C62.41.2, C62.45; Standard features include LED phase loss indication, EMI/RFI filter, surge counter with reset, dry contacts and audible alarm with silence button; Up to 10 Modes of Protection (L-N, L-L, L-G, N-G); 15-year warranty; ANSI/UL 1449 4th Edition, Type 1 SPD, File E210793; SPD module can be rotated 90 degrees depending on desired cable entry location; Field replaceable SPD module; RoHS Compliant; Available with or without disconnect switch; Ideal for new construction bid projects and specifications as well as existing facility retrofit
ZB T1 100kA 240/120V SP N4X T
ANSI/UL 1449 4th Edition, Type 1 SPD, File E210793; 15-year warranty; ANSI/IEEE C62.41.1, C62.41.2, C62.45; RoHS Compliant; CSA C22.2, Type 1 SPD; Field replaceable SPD module; UL96A Lightning Protection; Type 1 SPD for service entrance and facility-wide protection; Standard features include LED phase loss indication, EMI/RFI filter, surge counter with reset, dry contacts and audible alarm with silence button; SPD module can be rotated 90 degrees depending on desired cable entry location; Ideal for new construction bid projects and specifications as well as existing facility retrofit; Up to 10 Modes of Protection (L-N, L-L, L-G, N-G); Available with or without disconnect switch
ZB T1 200kA 240/120V SP N1
Available with or without disconnect switch; ANSI/IEEE C62.41.1, C62.41.2, C62.45; Up to 10 Modes of Protection (L-N, L-L, L-G, N-G); Standard features include LED phase loss indication, EMI/RFI filter, surge counter with reset, dry contacts and audible alarm with silence button; ANSI/UL 1449 4th Edition, Type 1 SPD, File E210793; Type 1 SPD for service entrance and facility-wide protection; Field replaceable SPD module; SPD module can be rotated 90 degrees depending on desired cable entry location; RoHS Compliant; 15-year warranty; UL96A Lightning Protection; CSA C22.2, Type 1 SPD; Ideal for new construction bid projects and specifications as well as existing facility retrofit
1-1/4X1/4 FUSE 250V 2/10A GDL
Glass body; Time-delay; 20A through 30A, 32VAC, UL Listed to U.S. and Canadian safety standards; 10A through 15A, 125VAC, UL Listed and CSA Certified; 1/16A through 8A, 250VAC, UL Listed and CSA Certified; 1/4” x 1-1/4”
32V 20A 1/4 X 1-1/4 FUSE
1/16A through 8A, 250VAC, UL Listed and CSA Certified; 20A through 30A, 32VAC, UL Listed to U.S. and Canadian safety standards; 1/4” x 1-1/4”; 10A through 15A, 125VAC, UL Listed and CSA Certified; Time-delay; Glass body
32V 25A 1/4 X 1-1/4 FUSE
10A through 15A, 125VAC, UL Listed and CSA Certified; 20A through 30A, 32VAC, UL Listed to U.S. and Canadian safety standards; 1/4” x 1-1/4”; Time-delay; Glass body; 1/16A through 8A, 250VAC, UL Listed and CSA Certified
1-1/4X1/4 FUSE 250V 3A GDL
Glass body; 20A through 30A, 32VAC, UL Listed to U.S. and Canadian safety standards; 1/4” x 1-1/4”; 1/16A through 8A, 250VAC, UL Listed and CSA Certified; 10A through 15A, 125VAC, UL Listed and CSA Certified; Time-delay
1-1/4X1/4 FUSE 250V 4/10A GDL
Time-delay; 1/4” x 1-1/4”; Glass body; 20A through 30A, 32VAC, UL Listed to U.S. and Canadian safety standards; 10A through 15A, 125VAC, UL Listed and CSA Certified; 1/16A through 8A, 250VAC, UL Listed and CSA Certified
250V 4/100A 1-1/4 X 1/4 FUSE
20A through 30A, 32VAC, UL Listed to U.S. and Canadian safety standards; 10A through 15A, 125VAC, UL Listed and CSA Certified; 1/16A through 8A, 250VAC, UL Listed and CSA Certified; 1/4” x 1-1/4”; Glass body; Time-delay
76159-FUSE 250V 1A 1-1/2X13/32
12 second time-delay at 200% rating; UL Listed to standard 248-14 (1/10 to 15A) File E33925; Numerous ratings for a wide variety of applications; 1 1/2” x 13/32” (10 mm x 38 mm) dimensions; For supplemental protection of circuits where time-delay and blown fuse indication are required, such as solenoid circuits or control circuits.; Can be used with UltraSafeā¢ fuse holders (1/10 – 10A); Pin indicator provides visual indication of open fuse or actuates switch for remote signaling; CSA Certified to Standard C22.2 No. 248.14 (1/10 to 15A)