69 GRB 17 D08P 55

69 GRB 17 D08P 55

Item #: G221013

Supplier Part #: G221013
Brand: Mersen

Extremely high breaking capacity fuses: Protection of power semiconductors as per IEC standard 60269-1 and -4 690V voltage rating as per IEC 33 gR class (current ratings 12 to 90A) as per VDE 636-23 - Clearing all overloads - Improved safety and protection - Enabling selective coordination with all fuses within distribution circuit aR class (current ratings 100A) according to VDE 636-23 and IEC 60269-4 Connection as per: - German standard DIN 43653/00C - British standard BS88-4 These fuses are UL Recognized
$491.52 /EA
NOT CURRENTLY IN STOCK

DII-SICHEINSATZ 4A GL-GG

Item #: G222163

Supplier Part #: G222163
Brand: Mersen

The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links is the protection of cables and power lines. They limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links "gG" also protect equipments and installations against dynamic effects of high short circuit currents.

Resistant to aging; Safe cut-off short circuits and over currents due to special design of fuse element; Insulated body suitable for high mechanical and thermal impacts; Optimized size; DIN VDE 0636-301; Free of lead, cadmium, mercury, chrome 6 (rohs conformity); Clear indication of operation condition due to coloured indicator on top contact; Top and bottom contacts made of nickel plated copper alloy; Low power dissipation

$26.98 /EA
NOT CURRENTLY IN STOCK

500V CP 10X38 AM 2A C/I FS

Item #: G222209

Supplier Part #: G222209
Brand: Mersen

Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. Size 10x38 is also available with striker. All cylindrical fuse-links have ceramic bodies and silver-plated contacts. Cylindrical fuse-links "aM" are partial range fuses. They protect electrical devices in case of unacceptable high short-circuit against destruction due high current limiting and low thermal let-through values. They cut off currents more than 6.3xln until the maximum breaking capacity (rated breaking capacity). Cylindrical fuse-links "aM" are mainly used for the protection of installation switch gear in otor circuit currents. For classification of the cylindrical fuse-links the nominal current of the fuse-link can be selected respective to the nominal current of the motor. Our technology and process was designed to ensure highly reliable technical performance.

Reduced size; Visual indication of fuse operation; Approved by various shipping organizations; IEC 60269-1 & -2 (electrically only for the range with striker); Optional indicator; Safest and most reliable protection system

$21.46 /EA
NOT CURRENTLY IN STOCK
DIII-RING-PASSEINSATZ 10A

DIII-RING-PASSEINSATZ 10A

Item #: G222922

Supplier Part #: G222922
Brand: Mersen

The D fuse-system is the first generation of the screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse-range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links gG is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents.

Low power dissipation; Resistant to aging; Safe cut off short circuits and over currents due to special design of fuse element; Insulated body suitable for high mechanical and thermal impacts; Top and bottom contacts made of nickel plated copper alloy; Free of lead, cadmium, mercury, chrome 6 (rohs conformity); Clear indication of operation condition due to coloured indicator on top contact; Optimized size

Call
NOT CURRENTLY IN STOCK
NH 000 32A 400V GG

NH 000 32A 400V GG

Item #: G223681

Supplier Part #: G223681
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

Lead free contact blades; Double indicator; Dimensions according to DIN 43 620 Parts 1 to 4; Non-isolated gripping lugs; 0% cadmium; IEC 60269-1 and -2; VDE 0636 Part 201

$130.06 /EA
NOT CURRENTLY IN STOCK
SC FUSE BLOCK A30QS 700-800A

SC FUSE BLOCK A30QS 700-800A

Item #: FH25F4

Supplier Part #: FH25F4
Brand: Mersen

Mersen P-Block series for Form 101 fuses are glass-filled polycarbonate or laminated phenolic insulator blocks with studs to accommodate bolt-in fuses. All studs, clips and mounting hardware are tin or zinc-plated

CSA Certified C22.2, class 6225, File 32169; Glass-filled polycarbonate or laminated phenolic insulator blocks with studs to accommodate bolt-in fuses; UL Recognized Component guide IZLT2 File E52283

$219.03 /EA
NOT CURRENTLY IN STOCK

SC FUSE BLOCK A50QS 700-800A

Item #: FH50F4

Supplier Part #: FH50F4
Brand: Mersen

Mersen P-Block series for Form 101 fuses are glass-filled polycarbonate or laminated phenolic insulator blocks with studs to accommodate bolt-in fuses. All studs, clips and mounting hardware are tin or zinc-plated

Glass-filled polycarbonate or laminated phenolic insulator blocks with studs to accommodate bolt-in fuses; UL Recognized Component guide IZLT2 File E52283; CSA Certified C22.2, class 6225, File 32169

$196.74 /EA
NOT CURRENTLY IN STOCK
SC FUSE BLOCK A50QS 900-1000A

SC FUSE BLOCK A50QS 900-1000A

Item #: FH50F5

Supplier Part #: FH50F5
Brand: Mersen

Mersen P-Block series for Form 101 fuses are glass-filled polycarbonate or laminated phenolic insulator blocks with studs to accommodate bolt-in fuses. All studs, clips and mounting hardware are tin or zinc-plated

UL Recognized Component guide IZLT2 File E52283; CSA Certified C22.2, class 6225, File 32169; Glass-filled polycarbonate or laminated phenolic insulator blocks with studs to accommodate bolt-in fuses

$185.62 /EA
NOT CURRENTLY IN STOCK
LOT DE 3 FUSG209996 FR24/63P

LOT DE 3 FUSG209996 FR24/63P

Item #: G227430

Supplier Part #: G227430
Brand: Mersen

FR-type fuses are designed to protect HV/LV power distribution transformers. Designed to be coordinated with other equipment, these current limiting fuse-links interrupt fault currents before they reach their peak. The fault current is interrupted inside the fuse-link body and although this is very fast, there is no sign of it outside. The main elements in these fuses are: a barrel of class F insulating synthetic material, nickel plated aluminium end contacts, pure silver fuse elements and a composite material fuse element holder to withstand high temperatures. Thanks to their structure, based on a synthetic material, FR fuse-links are the perfect answer to the stress involved in use inside HV bays and fuse-link chambers.

Average type striker: force 1 ±0.5 Joules; Back-up fuse links; IEC 62271-105; In accordance with:; 100% synthetic structure; Outstanding withstand to operating stresses; Superior mechanical strength; IEC 62271-107; High current limitation; IEC 60787; IEC/TR 62655; EDF Approval which guarantees high performances and quality of fuses manifactured (24kV); High breaking capacity

Call
NOT CURRENTLY IN STOCK

NH 00 100A 690V AM

Item #: G227867

Supplier Part #: G227867
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Non-isolated gripping lugs; IEC 60269-1 and -2; 0% cadmium; Double indicator; Lead free contact blades; Dimensions according to DIN 43 620 parts 1 to 4; VDE 0636 Part 201

$128.52 /EA
NOT CURRENTLY IN STOCK