Power Block SB 250
Halogen free plastic housing excluding the blue protection cover; Can be connected with round cross section cable or flat connection system like nVent ERIFLEX Flexibar Advanced or IBS/IBSB Advanced Insulated Braided Conductor; Conforms to EN 45545 obtaining an HL3 classification for chapter R23 and HL2 classification for chapter R22; RoHS; Tinned copper or aluminum block allows for copper or aluminum conductor direct connections, or using ferrule; Modular snap-together blocks for building multi-pole power blocks; RoHS compliant; EN 45545 – EN 45545-2:2013; CE, ERIFLEX SB – EN 60947-7-1; 95% fill ratio; Design allows for visual inspection of conductor and confirmation of connection; UR – ANSI/UL 1059; Easily clips onto DIN rail or mounts to panel with screws; Voltage detection and measurement connection; Screw retaining cover is hinged and removable; Compact power block with high short circuit current rating; UKCA, ERIFLEX SB – EN 60947-7-1
Distribution Block 2 Pole 40A - 16 Termi
CE, ERIFLEX BD – EN 60947-7-1; Protection cover and insulating screens are transparent; Easy and safe connections; RoHS compliant; Minimum space for maximum power; Easily clips onto DIN rail or mounts to panel with screws; EN 45545 – EN 45545-2:2013; RoHS; Conforms to EN 45545 obtaining an HL3 classification for chapter R23 and HL2 classification for chapter R22; UKCA, ERIFLEX BD – EN 60947-7-1; Halogen free; Insulating screen between each row
Distribution Block 4 Pole 80/100A - 6 Te
Insulating screen between each row; Minimum space for maximum power; Solid bars provide reliability; Easily clips onto DIN rail or mounts to panel with screws; Wiring with or without terminal; Halogen free; UKCA, ERIFLEX TD – EN 60947-7-1; EN 45545 – EN 45545-2:2013; RoHS compliant; Easy and safe connections; RoHS; Conforms to EN 45545 obtaining an HL3 classification for chapter R23 and HL2 classification for chapter R22; CE, ERIFLEX TD – EN 60947-7-1; Protection cover and insulating screens are transparent
Distribution Block 4 Pole 80/100ALL - 14
UKCA, ERIFLEX TD – EN 60947-7-1; CE, ERIFLEX TD – EN 60947-7-1; RoHS; RoHS compliant; Solid bars provide reliability; EN 45545 – EN 45545-2:2013; Conforms to EN 45545 obtaining an HL3 classification for chapter R23 and HL2 classification for chapter R22; Easy and safe connections; Insulating screen between each row; Halogen free; Protection cover and insulating screens are transparent; Easily clips onto DIN rail or mounts to panel with screws; Minimum space for maximum power; Wiring with or without terminal
Unipolar Distribution Block UDF 500A for
Tinned copper or aluminum block allows for copper or aluminum conductor direct connections, or using ferrule; Conforms to EN 45545 obtaining an HL3 classification for chapter R23 and HL2 classification for chapter R22; UKCA, ERIFLEX UD – EN 60947-7-1; RoHS compliant; Design allows for visual inspection of conductor and confirmation of connection; 95% fill ratio; UR – ANSI/UL 1059; Easily clips onto DIN rail or mounts to panel with screws; Screw retaining cover is hinged and removable; EN 45545 – EN 45545-2:2013; cUR – CSA C22.2 No. 158; Modular snap-together blocks for building multi-pole power blocks; Halogen free; RoHS; CE, ERIFLEX UD – EN 60947-7-1
ERIFLEX FLEXIBAR 3MTC 4X32X1
CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; UR – ANSI/UL 758; Reduces total installation cost; Bureau Veritas – ACE 14/163/02; RoHS compliant; Weight savings and material savings compared to wire alternatives; Thin layers of tinned electrolytic copper formed into a stack; Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint; Traceability codes and designation part numbers printed on insulation; CE, ERIFLEX FLEXIBAR – EN 61439-1; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; ABS; RoHS; Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld; EAC compliant; 100% production dielectric tested; Dramatically smaller and more flexible than comparable cable based on ampacity; UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F); Tinned copper allows for copper or aluminum conductor connections; Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility; UR – ANSI/UL 67, ANSI/UL 891; Better power density than cable with lower skin effect ratio; No lugs needed, reducing installation time and improving resistance to vibration
ERIFLEX FLEXIBAR 3MTC 6X32X1
Traceability codes and designation part numbers printed on insulation; UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F); CE, ERIFLEX FLEXIBAR – EN 61439-1; UR – ANSI/UL 67, ANSI/UL 891; EAC compliant; UR – ANSI/UL 758; Bureau Veritas – ACE 14/163/02; Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint; Dramatically smaller and more flexible than comparable cable based on ampacity; 100% production dielectric tested; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; Tinned copper allows for copper or aluminum conductor connections; Thin layers of tinned electrolytic copper formed into a stack; Reduces total installation cost; ABS; RoHS compliant; CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility; No lugs needed, reducing installation time and improving resistance to vibration; Better power density than cable with lower skin effect ratio; Weight savings and material savings compared to wire alternatives; RoHS; Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld
ERIFLEX FLEXIBAR 3MTC 5X63X1
CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; Better power density than cable with lower skin effect ratio; Traceability codes and designation part numbers printed on insulation; UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F); Reduces total installation cost; UR – ANSI/UL 758; RoHS; No lugs needed, reducing installation time and improving resistance to vibration; Tinned copper allows for copper or aluminum conductor connections; EAC compliant; Dramatically smaller and more flexible than comparable cable based on ampacity; Bureau Veritas – ACE 14/163/02; ABS; CE, ERIFLEX FLEXIBAR – EN 61439-1; UR – ANSI/UL 67, ANSI/UL 891; Thin layers of tinned electrolytic copper formed into a stack; 100% production dielectric tested; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility; Weight savings and material savings compared to wire alternatives; Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint; Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld; RoHS compliant
ERIFLEX FLEXIBAR 3MTC 8X63X1
Traceability codes and designation part numbers printed on insulation; UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F); EAC compliant; Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility; CE, ERIFLEX FLEXIBAR – EN 61439-1; UR – ANSI/UL 758; UR – ANSI/UL 67, ANSI/UL 891; Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint; 100% production dielectric tested; ABS; RoHS; Thin layers of tinned electrolytic copper formed into a stack; Dramatically smaller and more flexible than comparable cable based on ampacity; CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; Reduces total installation cost; No lugs needed, reducing installation time and improving resistance to vibration; Weight savings and material savings compared to wire alternatives; Tinned copper allows for copper or aluminum conductor connections; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; RoHS compliant; Better power density than cable with lower skin effect ratio; Bureau Veritas – ACE 14/163/02; Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld
ERIFLEX FLEXIBAR 3MTC 3X80X1
Dramatically smaller and more flexible than comparable cable based on ampacity; Reduces total installation cost; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld; RoHS; Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint; No lugs needed, reducing installation time and improving resistance to vibration; Bureau Veritas – ACE 14/163/02; Traceability codes and designation part numbers printed on insulation; Thin layers of tinned electrolytic copper formed into a stack; UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F); UR – ANSI/UL 758; Better power density than cable with lower skin effect ratio; ABS; Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility; Tinned copper allows for copper or aluminum conductor connections; CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; 100% production dielectric tested; CE, ERIFLEX FLEXIBAR – EN 61439-1; UR – ANSI/UL 67, ANSI/UL 891; RoHS compliant; EAC compliant; Weight savings and material savings compared to wire alternatives