Browse Categories

Connectors

Power Products/Connectors 
Viewing Page 9 of 9 (83 results)
ERIFLEX FLEXIBAR 3MTC 8X80X1

ERIFLEX FLEXIBAR 3MTC 8X80X1

Item #: 505543

Supplier Part #: FLEX3MTC8X80X1
Brand: nVent Eriflex

nVent ERIFLEX Flexibar, Tinned Copper, 1,600 A, UL 67, UL 758 Certification Details, 3.15" x 0.039", 1,263.06 kcmil

Better power density than cable with lower skin effect ratio; No lugs needed, reducing installation time and improving resistance to vibration; UR – ANSI/UL 67, ANSI/UL 891; Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility; Tinned copper allows for copper or aluminum conductor connections; Bureau Veritas – ACE 14/163/02; RoHS; CE, ERIFLEX FLEXIBAR – EN 61439-1; UR – ANSI/UL 758; Thin layers of tinned electrolytic copper formed into a stack; Dramatically smaller and more flexible than comparable cable based on ampacity; 100% production dielectric tested; RoHS compliant; Traceability codes and designation part numbers printed on insulation; ABS; Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint; Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld; CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F); cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; Weight savings and material savings compared to wire alternatives; EAC compliant; Reduces total installation cost

Call
NOT CURRENTLY IN STOCK
ERIFLEX FLEXIBAR 3MTC 5X100X1

ERIFLEX FLEXIBAR 3MTC 5X100X1

Item #: 505546

Supplier Part #: FLEX3MTC5X100X1
Brand: nVent Eriflex

nVent ERIFLEX Flexibar, Tinned Copper, 1,600 A, UL 67, UL 758 Certification Details, 3.937" x 0.039", 986.76 kcmil

UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F); Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint; Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld; UR – ANSI/UL 67, ANSI/UL 891; Bureau Veritas – ACE 14/163/02; Dramatically smaller and more flexible than comparable cable based on ampacity; RoHS compliant; Thin layers of tinned electrolytic copper formed into a stack; RoHS; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; No lugs needed, reducing installation time and improving resistance to vibration; ABS; Better power density than cable with lower skin effect ratio; EAC compliant; CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility; UR – ANSI/UL 758; Weight savings and material savings compared to wire alternatives; Reduces total installation cost; 100% production dielectric tested; Tinned copper allows for copper or aluminum conductor connections; Traceability codes and designation part numbers printed on insulation; CE, ERIFLEX FLEXIBAR – EN 61439-1

Call
NOT CURRENTLY IN STOCK
ERIFLEX FLEXIBAR 3MTC 10X100X1

ERIFLEX FLEXIBAR 3MTC 10X100X1

Item #: 505549

Supplier Part #: FLEX3MTC10X100
Brand: nVent Eriflex

nVent ERIFLEX Flexibar, Tinned Copper, 2,000 A, UL 67, UL 758 Certification Details, 3.937" x 0.039", 1,973.52 kcmil

CSA – CSA C22.2 No. 0, CSA C22.2 No. 210; Bureau Veritas – ACE 14/163/02; 100% production dielectric tested; cUR – CSA C22.2 No. 29, CSA C22.2 No. 244; Weight savings and material savings compared to wire alternatives; ABS; Better power density than cable with lower skin effect ratio; Tinned copper allows for copper or aluminum conductor connections; Thin layers of tinned electrolytic copper formed into a stack; Traceability codes and designation part numbers printed on insulation; RoHS; No lugs needed, reducing installation time and improving resistance to vibration; UR – ANSI/UL 67, ANSI/UL 891; RoHS compliant; Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint; CE, ERIFLEX FLEXIBAR – EN 61439-1; UR – ANSI/UL 758; Insulated by high-resistance, self-extinguishing PVC with less than 20% contact with conductor for high flexibility; Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld; UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F); Reduces total installation cost; Dramatically smaller and more flexible than comparable cable based on ampacity; EAC compliant

Call
NOT CURRENTLY IN STOCK
  • « PREV
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9