Search in Category
Filter Your Search
Shop by Category
Fuses
1-1/4X1/4 FUSE 250V 10A GSA
1/4” x 1-1/4”; Time-delay; 20A, 250VAC, 25 & 30A, 125VAC; 10, 12, 15A, 250V UL Recognized; 1/16A through 8A, 250VAC, CSA Certified; Ceramic body; 1/16A through 8A, 250VAC, UL Listed; 10, 12, 15A, 250V CSA Recognized
600V 60A CLASS J HS FUSE
Control panels; Excellent cycling ability for frequent starts/stops without nuisance opening; Solid state relays; Low I2t (low thermal energy); Branch circuits; UL listed to standard 248-8 File E2137; Electronic motor controllers; Optimized over-load capability for withstanding elevated levels of current during electronic motor controller starts; DC listed to UL 248; Phase controllers; Drives; Soft-starters; CSA certified to standard C22.2 no. 248.8
SHAFT PISTOL HANDLE 6X6X360MM
250V 5A 2x9/16 RK5 TD FUS
Service entrance equipment; CSA certified to standard C22.2 no. 248.12; Motor circuits; Metal-embossed date and catalog number for traceability and lasting identification; High-grade silica filler ensures fast arc quenching and high current limitation; Mains; Branch circuits; Current-limiting for low peak let-thru current; Transformers; UL listed to standard 248-12 File E2137; Time-delay; Optional solid state SmartSpot blown fuse indicator; Current-limiting; AC & DC rated; Easy-to-read label for quick brand recognition and replacement; Fiberglass body provides dimensional stability in harsh industrial settings; DC listed to UL standard 248 TRS only; General-purpose equipment; Feeders; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Rejection-style design prevents replacement errors (when used with recommended fuse blocks)
SPD ST 120/208V 3PH WYE+MS
DIN-rail mountable; IP20 finger-safe design; Small footprint; 2-year warranty; RoHS Compliant; Remote indicator (optional); Visual indicator; Easy installation or retrofit; ANSI/UL 1449 4th Edition, Type 1 Component Assembly SPD, File E210793; No additional overcurrent protection devices required; ANSI/IEEE C62.41.1, C62.41.2, C62.45; Fail-safe, self-protected design
600V 400A TD RK5 FUSE SMARTSPO
Current-limiting for low peak let-thru current; UL listed to standard 248-12 File E2137; Transformers; Mains; Fiberglass body provides dimensional stability in harsh industrial settings; Time-delay; General-purpose equipment; Feeders; AC & DC rated; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Service entrance equipment; CSA certified to standard C22.2 no. 248.12; Branch circuits; DC listed to UL standard 248 TRS only; Easy-to-read label for quick brand recognition and replacement; Motor circuits; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Current-limiting; Optional solid state SmartSpot blown fuse indicator; High-grade silica filler ensures fast arc quenching and high current limitation; Metal-embossed date and catalog number for traceability and lasting identification
XR T1 50kA 600Y/347V ALM
NEMA 4X enclosure for outdoor or indoor use; Fits 3/4” knockouts with 3’ leads for easy installation; ANSI/UL 1449 4th Edition, Type 1 SPD, File E210793; RoHS Compliant; LED status indicator (ON = Good, OFF = Replace); Optional audible alarm and remote dry contacts; For use in ANSI/UL Type 1 or 2 SPD installations; UL96A Lightning Protection; Optional mounting bracket for surface mount applications; 5-year warranty; CSA C22.2, Type 1 SPD; ANSI/IEEE C62.41.1, C62.41.2, C62.45; Up to 10 modes of Protection (L-N, L-L, L-G optional, N-G optional); Designed with the industry leading Mersen TPMOV® Technology
250V 8A 2x9/16 RK5 TD FUS
DC listed to UL standard 248 TRS only; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Feeders; Time-delay; CSA certified to standard C22.2 no. 248.12; General-purpose equipment; High-grade silica filler ensures fast arc quenching and high current limitation; Current-limiting; Optional solid state SmartSpot blown fuse indicator; Current-limiting for low peak let-thru current; Motor circuits; Mains; Branch circuits; Service entrance equipment; Fiberglass body provides dimensional stability in harsh industrial settings; AC & DC rated; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); UL listed to standard 248-12 File E2137; Easy-to-read label for quick brand recognition and replacement; Metal-embossed date and catalog number for traceability and lasting identification; Transformers
60A J 1P ULTRASAFE W/IND
Finger-safe IP20 protection; Optional indicator lights; IEC certified 60269-1, 60947-3; UL Listed, guide IZLT File E52283; DIN-rail mount; Quick, easy fuse change; CSA Certified C22.2, class 6225 01, File 32169; Compact footprint
600V 30A SP MID ULTSFE W/IND
ATM, DCT, ATMR recommended for DC applications; IEC 60269-2-1 and 60947-3 Compliant (USM only); Optional visual blown fuse Indicator lights; Quick, tool-free, easy fuse change outs; CSA Certified C22.2; Compact footprint; UL Listed to Standard 4248- 4 (class CC) and 4248-1 (midget), File E52283; IP20 Finger-Safe (touch safe); UL Listed to standard 4248-18 (photovoltaic), File E347822; DIN-rail mounting