Browse Categories

Search in Category

Fuses

Filter Your Search

Hide Attribute Current
Hide Attribute Degree of protection (IP)
Hide Attribute Weight

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 152 of 1000 (10,000+ results)

NH 3 630A 500V AM

Item #: M227987

Supplier Part #: M227987
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Lead free contact blades; 0% cadmium; VDE 0636 Part 201; Double indicator; Dimensions according to DIN 43 620 parts 1 to 4; Non-isolated gripping lugs; IEC 60269-1 and -2

$356.37 /EA
NOT CURRENTLY IN STOCK

NH 000 25A 690V GG

Item #: M228447

Supplier Part #: M228447
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Non-isolated gripping lugs; Dimensions according to DIN 43 620 parts 1 to 4; IEC 60269-1 and -2; Double indicator; 0% cadmium; VDE 0636 Part 201; Lead free contact blades

$123.49 /EA
NOT CURRENTLY IN STOCK

NH 0 50A 690V GG

Item #: M228470

Supplier Part #: M228470
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Dimensions according to DIN 43 620 parts 1 to 4; IEC 60269-1 and -2; VDE 0636 Part 201; 0% cadmium; Double indicator; Non-isolated gripping lugs; Lead free contact blades

$156.37 /EA
NOT CURRENTLY IN STOCK

NH 2 63A 690V GG

Item #: M228493

Supplier Part #: M228493
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Dimensions according to DIN 43 620 parts 1 to 4; IEC 60269-1 and -2; Lead free contact blades; Non-isolated gripping lugs; Double indicator; 0% cadmium; VDE 0636 Part 201

$232.78 /EA
NOT CURRENTLY IN STOCK
NH 000 32A 690V GG SGL

NH 000 32A 690V GG SGL

Item #: M229712

Supplier Part #: M229712
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Dimensions according to DIN 43 620 Parts 1 to 4; Double indicator; VDE 0636 Part 201; Isolated metal gripping lugs (SGL); IEC 60269-1 and -2; Lead free contact blades; 0% cadmium

$135.70 /EA
NOT CURRENTLY IN STOCK
NH 0 63A 690V GG SGL

NH 0 63A 690V GG SGL

Item #: M229735

Supplier Part #: M229735
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Isolated metal gripping lugs (SGL); VDE 0636 Part 201; 0% cadmium; Lead free contact blades; IEC 60269-1 and -2; Dimensions according to DIN 43 620 Parts 1 to 4; Double indicator

$172.06 /EA
NOT CURRENTLY IN STOCK
NH 2 355A 690V GG SGL

NH 2 355A 690V GG SGL

Item #: M229758

Supplier Part #: M229758
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Dimensions according to DIN 43 620 Parts 1 to 4; Double indicator; IEC 60269-1 and -2; VDE 0636 Part 201; Isolated metal gripping lugs (SGL); 0% cadmium; Lead free contact blades

$277.09 /EA
NOT CURRENTLY IN STOCK
A30QS 15-1

A30QS 15-1

Item #: M230011

Supplier Part #: M230011
Brand: Mersen

A30QS Amp-trap Semiconductor Protection fuses are intended for the protection of Power Semiconductors such as Diodes, Phase Control SCR's and other power Semiconductor devices. The A30QS is recommended for new applications providing solutions for your critical protection needs at 300V and less semiconductors

Low I 2 t minimizes damage to protected component on short circuit.; 300VAC and 300VDC rated; Controlled arc Voltage reduces stress to circuit components during fuse clearing.; Choice of mounting types helps in equipment design

$24.36 /EA
NOT CURRENTLY IN STOCK

NH 000 6A 500V AM

Item #: M232495

Supplier Part #: M232495
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Double indicator; Lead free contact blades; Dimensions according to DIN 43 620 parts 1 to 4; VDE 0636 Part 201; Non-isolated gripping lugs; 0% cadmium; IEC 60269-1 and -2

$133.49 /EA
NOT CURRENTLY IN STOCK

NH 2 355A 500V AM

Item #: M232518

Supplier Part #: M232518
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Non-isolated gripping lugs; Dimensions according to DIN 43 620 parts 1 to 4; Lead free contact blades; VDE 0636 Part 201; Double indicator; IEC 60269-1 and -2; 0% cadmium

$288.01 /EA
NOT CURRENTLY IN STOCK
  • « PREV
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • NEXT »