UL98 SWITCH 200A 3P 1+2 POS

Item #: M200U12

Supplier Part #: M200U12
Brand: Mersen

Mersen disconnect switches are extremely durable and versatile. These heavy-duty switches are designed with the most up-to-date disconnect switch technology available. Designed to suit the UL98 standard, the switch gives you a product that makes and breaks power circuits on load. The switches are tested and approved for use in demanding applications, such as Service Entrance.

Flexible mounting; Front or side operation; IEC 60947-3; Adjustable shaft depth; All UL switches meet the requirements of UL and CSA; Flange mounting accessories; Most compact size; Service entrance rated; UL listed guide WHTY, File E191605 for UL 98 (ratings from 30 A to 1200 A); Internally mounted auxiliary contacts

$705.53 /EA
NOT CURRENTLY IN STOCK

UL98 Switch 200A 3p

Item #: M200U30

Supplier Part #: M200U30
Brand: Mersen

Mersen disconnect switches are extremely durable and versatile. These heavy-duty switches are designed with the most up-to-date disconnect switch technology available. Designed to suit the UL98 standard, the switch gives you a product that makes and breaks power circuits on load. The switches are tested and approved for use in demanding applications, such as Service Entrance.

Flexible mounting; Flange mounting accessories; Service entrance rated; Adjustable shaft depth; Front or side operation; Internally mounted auxiliary contacts; UL listed guide WHTY, File E191605 for UL 98 (ratings from 30 A to 1200 A); All UL switches meet the requirements of UL and CSA; Most compact size; IEC 60947-3

$645.04 /EA
NOT CURRENTLY IN STOCK

690V CP 22X58 GG 25A P FS

Item #: M201307

Supplier Part #: M201307
Brand: Mersen

Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. Size 10x38 is also available with striker. All cylindrical fuse-links have ceramic bodies and silver-plated contacts. Cylindrical fuse-links "gG" are used for the protection of cables, motors and LV-networks. They limit and cut off unacceptable overcurrents and short-circuit currents up to their nominal breaking capacity. Cylindrical fuse-links "gG" also protect electrical equipment and installations against the dynamic effect of high short-currents. Our technology and process was designed to ensure highly reliable technical performance.

Reduced size; Approved by Lloyd’s Register of Shipping and Bureau Veritas; Safest and most reliable protection system; IEC 60269-1 & -2; Striker version available for remote indication of fuse operation; Full range protection

$50.41 /EA
NOT CURRENTLY IN STOCK
DIV-RECTIEINSATZ 100A 500V GR

DIV-RECTIEINSATZ 100A 500V GR

Item #: M201767

Supplier Part #: M201767
Brand: Mersen

The D fuse-system is the first generation of screw fuse-systems in the German DIN standard. It is still used in many installations. This D system comprises the sizes DII, DIII, DIV, DV. Those D ultra-fast acting “gR” ranges are dedicated to semi-conductor protection, in applications where fuse-links are accessible to non-trained persons and can also be changed by them. They are used for the protection of components such as diodes, thyristors or AC/DC motor drives. The “R” stands for the English word Rectifier. D fuse-links are available at the rated current range from 2A up to 200A.

Insulated body suitable for high mechanical and thermal impacts; Resistant to aging; Safe cut off short circuits and over currents due special design of fuse element; Top and bottom contacts made of nickel-plated/silver-plated copper alloy; DIN EN 60269-4 (VDE 0636-4); DIN VDE 0636-3; Clear indication of operation condition due coloured indicator on top contact; Low power dissipation; Optimized size; IEC 60 269-4

$154.20 /EA
NOT CURRENTLY IN STOCK
H 1209P BCKUP 292-56/40

H 1209P BCKUP 292-56/40

Item #: M209311

Supplier Part #: M209311
Brand: Mersen

Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor®-P HV fuses are back-up fuses as defined in the IEC 60282-1 standard and dedicated to protect transformers against effects of short-circuit currents. To guarantee high quality, Mersen uses the best materials fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic.

Indoor and outdoor applications; IEC 60282-1; Low switching voltage; VDE 0670 part 4; High current limitation; Coordination with IEC 60787, IEC 62271-105, IEC/TR 62655; DIN 43625; Energy efficency; New cap design for a better compatibility with all types of clips and easier assembly; Quick breaking; Medium striker 80N/30mm

$782.84 /EA
NOT CURRENTLY IN STOCK

NH 2 40A 500V GG

Item #: M211082

Supplier Part #: M211082
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Double indicator; Non-isolated gripping lugs; IEC 60269-1 and -2; Dimensions according to DIN 43 620 parts 1 to 4; 0% cadmium; Lead free contact blades; VDE 0636 Part 201

$232.78 /EA
NOT CURRENTLY IN STOCK

690V CP 22X58 AM 16A S/I FS

Item #: M211565

Supplier Part #: M211565
Brand: Mersen

Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. Size 10x38 is also available with striker. All cylindrical fuse-links have ceramic bodies and silver-plated contacts. Cylindrical fuse-links "aM" are partial range fuses. They protect electrical devices in case of unacceptable high short-circuit against destruction due high current limiting and low thermal let-through values. They cut off currents more than 6.3xln until the maximum breaking capacity (rated breaking capacity). Cylindrical fuse-links "aM" are mainly used for the protection of installation switch gear in otor circuit currents. For classification of the cylindrical fuse-links the nominal current of the fuse-link can be selected respective to the nominal current of the motor. Our technology and process was designed to ensure highly reliable technical performance.

Approved by Lloyd’s Register of Shipping and Bureau Veritas; Reduced size; Striker version available for remote indication of fuse operation; IEC 60269-1 & -2; Safest and most reliable protection system

$40.64 /EA
NOT CURRENTLY IN STOCK
D02-SICHSOCKEL 3POL RAIL

D02-SICHSOCKEL 3POL RAIL

Item #: M211979

Supplier Part #: M211979
Brand: Mersen

The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. This system is the newest generation of screw fuse-system in the german DIN standard and is designed for 400VAC/250VDC networks. The D0 fuse-bases are available in the sizes D01, D02 and D03. D0 fuse-bases are used in combination with D0 fuse-links for the protection of cables and power lines. D0 fuse-links limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. They also protect equipments and installations against dynamic effects of high short circuit currents.

Resistant to aging; DIN VDE 0636-3; Clear indication of operation condition due coloured indicator un top contact; Insulated body suitable for high mechanical and thermal impacts; Safe cut-off short circuits and over currents due to special design of fuse element; DIN EN 60715; Low power dissipation; Optimized size; Top and bottom contacts made of nickel plated copper alloy

$204.66 /EA
NOT CURRENTLY IN STOCK

NH 000 4A 500V GG

Item #: M212462

Supplier Part #: M212462
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

VDE 0636 Part 201; Double indicator; Dimensions according to DIN 43 620 parts 1 to 4; Lead free contact blades; 0% cadmium; IEC 60269-1 and -2; Non-isolated gripping lugs

$119.44 /EA
NOT CURRENTLY IN STOCK
NDZ-RING-PASSEINSATZ 4A

NDZ-RING-PASSEINSATZ 4A

Item #: M213060

Supplier Part #: M213060
Brand: Mersen

The D fuse-system is the first generation of the screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse-range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links gG is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents.

Insulated body suitable for high mechanical and thermal impacts; Safe cut off short circuits and over currents due to special design of fuse element; Low power dissipation; Resistant to aging; Top and bottom contacts made of nickel plated copper alloy; Free of lead, cadmium, mercury, chrome 6 (rohs conformity); Optimized size; Clear indication of operation condition due to coloured indicator on top contact

Call