Search in Category
Filter Your Search
Shop by Category
Fuses
SWITCHFUS 100A J R 3+0+N POS
IEC 60947-3; All UL Fusible Disconnect Switches meet UL & CSA requirements; Adjustable shaft depth; Fuse monitoring; Interlocked fuse doors; UL listed guide WHTY, File E191605 for UL 98 (ratings from 30A to 1200A); Power taps; Multiple Configurations; Double break, isolating live and load side of fuse
IEC UL98 Switch 100A 3p
Most compact size; Flexible mounting; Adjustable shaft depth; Service entrance rated; IEC 60947-3; UL listed guide WHTY, File E191605 for UL 98 (ratings from 30 A to 1200 A); Internally mounted auxiliary contacts; Flange mounting accessories; All UL switches meet the requirements of UL and CSA; Front or side operation
IEC UL98 Switch 100A 3p DM
Front or side operation; IEC 60947-3; Flange mounting accessories; Service entrance rated; Most compact size; All UL switches meet the requirements of UL and CSA; Internally mounted auxiliary contacts; UL listed guide WHTY, File E191605 for UL 98 (ratings from 30 A to 1200 A); Flexible mounting; Adjustable shaft depth
1500VDC NH3L gPV 350A
(E358319, Volume 1, Section 1); Durable construction for enhanced system longevity; Temperature cycle withstand capability; Low fault current interrupting capability; IEC 60269-6; RoHS compliance; High efficiency with low power losses; UL 4248-19 for fuseholders, Photovoltaic; UL 248-19 for fuses (pending for 1XL, 2XL); (E362644 Volume 1); Global acceptance
SWITCHFUS 1200A L 1+2 POS
Fuse monitoring; Interlocked fuse doors; All UL Fusible Disconnect Switches meet UL & CSA requirements; Double break, isolating live and load side of fuse; Multiple Configurations; IEC 60947-3; UL listed guide WHTY, File E191605 for UL 98 (ratings from 30A to 1200A); Power taps; Adjustable shaft depth
Switchfus 1200A L R 3+0 pos
Multiple Configurations; Power taps; Double break, isolating live and load side of fuse; UL listed guide WHTY, File E191605 for UL 98 (ratings from 30A to 1200A); Adjustable shaft depth; IEC 60947-3; All UL Fusible Disconnect Switches meet UL & CSA requirements; Fuse monitoring; Interlocked fuse doors
SWITCHFUS 1200A L R 4+0 POS
Fuse monitoring; Power taps; Double break, isolating live and load side of fuse; IEC 60947-3; Interlocked fuse doors; Multiple Configurations; All UL Fusible Disconnect Switches meet UL & CSA requirements; UL listed guide WHTY, File E191605 for UL 98 (ratings from 30A to 1200A); Adjustable shaft depth
UL98 Switch 1200A 3p
Flange mounting accessories; Front or side operation; Internally mounted auxiliary contacts; All UL switches meet the requirements of UL and CSA; IEC 60947-3; Flexible mounting; UL listed guide WHTY, File E191605 for UL 98 (ratings from 30 A to 1200 A); Most compact size; Adjustable shaft depth; Service entrance rated