55KV 50E E RATED CLIP-LOCK

55KV 50E E RATED CLIP-LOCK

Item #: A055C1D0R0-50E

Supplier Part #: A055C1D0R0-50E
Brand: Mersen

Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.

Some UL Listed to standard File E143362; UL listed for compatibility with UL listed equipment; Blown-fuse indicator to give positive identification of open fuse; Clip-lock mounting for reliable high integrity connection into circuit; 2 lb tripped force – 0.50 Inch; Non-venting for silent operation; Metal embossed catalog number and manufacturing date for lasting identification; Current-limiting for superior equipment protection

$1,037.17 /EA
NOT CURRENTLY IN STOCK
55KV 65E E RATED CLIP-LOCK

55KV 65E E RATED CLIP-LOCK

Item #: A055C1D0R0-65E

Supplier Part #: A055C1D0R0-65E
Brand: Mersen

Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.

Non-venting for silent operation; Some UL Listed to standard File E143362; UL listed for compatibility with UL listed equipment; Metal embossed catalog number and manufacturing date for lasting identification; 2 lb tripped force – 0.50 Inch; Clip-lock mounting for reliable high integrity connection into circuit; Blown-fuse indicator to give positive identification of open fuse; Current-limiting for superior equipment protection

$1,082.24 /EA
NOT CURRENTLY IN STOCK
55KV 80E E RATED CLIP-LOCK

55KV 80E E RATED CLIP-LOCK

Item #: A055C1D0R0-80E

Supplier Part #: A055C1D0R0-80E
Brand: Mersen

Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.

Metal embossed catalog number and manufacturing date for lasting identification; Blown-fuse indicator to give positive identification of open fuse; UL listed for compatibility with UL listed equipment; Some UL Listed to standard File E143362; Clip-lock mounting for reliable high integrity connection into circuit; 2 lb tripped force – 0.50 Inch; Current-limiting for superior equipment protection; Non-venting for silent operation

$1,082.24 /EA
NOT CURRENTLY IN STOCK
55KV 450E E RATED CLIP-LOCK

55KV 450E E RATED CLIP-LOCK

Item #: A055C2D0R0-450E

Supplier Part #: A055C2D0R0-450E
Brand: Mersen

Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.

2 lb tripped force – 0.50 Inch; Non-venting for silent operation; Clip-lock mounting for reliable high integrity connection into circuit; Some UL Listed to standard File E143362; UL listed for compatibility with UL listed equipment; Current-limiting for superior equipment protection; Metal embossed catalog number and manufacturing date for lasting identification; Blown-fuse indicator to give positive identification of open fuse

$3,706.09 /EA
NOT CURRENTLY IN STOCK
55KV 500E E RATED CLIP-LOCK

55KV 500E E RATED CLIP-LOCK

Item #: A055C2D0R0-500E

Supplier Part #: A055C2D0R0-500E
Brand: Mersen

Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.

Clip-lock mounting for reliable high integrity connection into circuit; 2 lb tripped force – 0.50 Inch; Non-venting for silent operation; UL listed for compatibility with UL listed equipment; Metal embossed catalog number and manufacturing date for lasting identification; Current-limiting for superior equipment protection; Blown-fuse indicator to give positive identification of open fuse; Some UL Listed to standard File E143362

$4,407.82 /EA
NOT CURRENTLY IN STOCK
55KV 600E E RATED CLIP-LOCK

55KV 600E E RATED CLIP-LOCK

Item #: A055C2D0R0-600E

Supplier Part #: A055C2D0R0-600E
Brand: Mersen

Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.

UL listed for compatibility with UL listed equipment; Current-limiting for superior equipment protection; Blown-fuse indicator to give positive identification of open fuse; Metal embossed catalog number and manufacturing date for lasting identification; Clip-lock mounting for reliable high integrity connection into circuit; 2 lb tripped force – 0.50 Inch; Some UL Listed to standard File E143362; Non-venting for silent operation

$4,483.32 /EA
NOT CURRENTLY IN STOCK
55KV442mm3DIAMV FUSE 12R

55KV442mm3DIAMV FUSE 12R

Item #: A055D1DSR0-12R

Supplier Part #: A055D1DSR0-12R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Current-limiting for superior equipment protection; UL recognized component File E93367; Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”

$1,355.40 /EA
NOT CURRENTLY IN STOCK
55KV442mm3DIAMV FUSE 13R

55KV442mm3DIAMV FUSE 13R

Item #: A055D1DSR0-13R

Supplier Part #: A055D1DSR0-13R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; UL recognized component File E93367; Current-limiting for superior equipment protection

$1,355.40 /EA
NOT CURRENTLY IN STOCK
55KV442mm3DIAMV FUSE 16R

55KV442mm3DIAMV FUSE 16R

Item #: A055D1DSR0-16R

Supplier Part #: A055D1DSR0-16R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

UL recognized component File E93367; Current-limiting for superior equipment protection; Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”

$1,355.40 /EA
NOT CURRENTLY IN STOCK
55KV442mm3DIAMV FUSE 19R

55KV442mm3DIAMV FUSE 19R

Item #: A055D1DSR0-19R

Supplier Part #: A055D1DSR0-19R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; UL recognized component File E93367; Current-limiting for superior equipment protection

$1,355.40 /EA