Fuses
250V 90A RK1 TD FUSE
600VAC & 600VDC dual rated; Extremely current-limiting for low peak let-thru current; Reduced inventory by taking the place of class RK5, K, and H fuses; UL listed to standard 248-12 File E2137; CSA certified to standard C22.2 No. 248.12; Safety switches; All general-purpose circuits; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Metal-embossed date and catalog number for easier traceability and lasting identification; Recommended for Arc Flash energy reduction; High-visibility orange label gives instant brand recognition; Branch circuit protection; Fiberglass body provides dimensional stability in harsh industrial settings; DC listed to UL standard 248; Control panels; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Disconnects; Transformers; Motors; Time-delay for motor starting and transformer inrush currents without nuisance opening; 300kA interrupting rating – self-certified, UL witnessed tests; Solid state SmartSpot visual blown fuse indicator
250V 9A RK1 TD FUSE
Control panels; UL listed to standard 248-12 File E2137; All general-purpose circuits; 600VAC & 600VDC dual rated; 300kA interrupting rating – self-certified, UL witnessed tests; CSA certified to standard C22.2 No. 248.12; Time-delay for motor starting and transformer inrush currents without nuisance opening; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Metal-embossed date and catalog number for easier traceability and lasting identification; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Extremely current-limiting for low peak let-thru current; Recommended for Arc Flash energy reduction; Fiberglass body provides dimensional stability in harsh industrial settings; Reduced inventory by taking the place of class RK5, K, and H fuses; Disconnects; DC listed to UL standard 248; Solid state SmartSpot visual blown fuse indicator; High-visibility orange label gives instant brand recognition; Motors; Transformers; Branch circuit protection; Safety switches
250V 100A RK1 FUSE
Self-certified for DC per UL248; UL listed to standard 248-12 File E2137; Rejection style design prevents replacement by other fuse classes; Panelboards; Feeder circuits; Lighting circuits; Non-inductive loads; Bus duct; CSA certified to standard C22.2 No. 248.12; Switchboards; Load centers; Easy-to-read imprint label for quick recognition and replacement; Fiberglass body provides dimensional stability in harsh industrial environments; High degree of current limitation for low peak let-thru current
250V 10A RK1 FUSE
CSA certified to standard C22.2 No. 248.12; Rejection style design prevents replacement by other fuse classes; Fiberglass body provides dimensional stability in harsh industrial environments; Non-inductive loads; Panelboards; Feeder circuits; High degree of current limitation for low peak let-thru current; UL listed to standard 248-12 File E2137; Switchboards; Load centers; Lighting circuits; Bus duct; Easy-to-read imprint label for quick recognition and replacement; Self-certified for DC per UL248
250V 125A RK1 FUSE
Bus duct; Load centers; Self-certified for DC per UL248; Panelboards; Rejection style design prevents replacement by other fuse classes; Easy-to-read imprint label for quick recognition and replacement; Non-inductive loads; High degree of current limitation for low peak let-thru current; CSA certified to standard C22.2 No. 248.12; Switchboards; Fiberglass body provides dimensional stability in harsh industrial environments; Feeder circuits; UL listed to standard 248-12 File E2137; Lighting circuits
93572-FUSEFORM 480
Capacitor inrush withstand capability; Tested by UL to CSA standard C22.2 No. 248.1; UL Recognized Component File E60314; Direct mount; High interrupting rating; Current-limiting; Optional blown fuse indication
93559-FUSEFORM 480
Current-limiting; High interrupting rating; Optional blown fuse indication; Capacitor inrush withstand capability; Direct mount; UL Recognized Component File E60314; Tested by UL to CSA standard C22.2 No. 248.1
CAP FUSE 600V 15A
Capacitor inrush withstand capability; Current-limiting; UL Recognized Component File E60314; Optional blown fuse indication; High interrupting rating; Direct mount; Tested by UL to CSA standard C22.2 No. 248.1
250V 300A RK1 FUSE
Non-inductive loads; CSA certified to standard C22.2 No. 248.12; Lighting circuits; Switchboards; Self-certified for DC per UL248; Easy-to-read imprint label for quick recognition and replacement; Feeder circuits; Fiberglass body provides dimensional stability in harsh industrial environments; UL listed to standard 248-12 File E2137; Load centers; Panelboards; Bus duct; Rejection style design prevents replacement by other fuse classes; High degree of current limitation for low peak let-thru current
250V 400A RK1 FUSE
Feeder circuits; Lighting circuits; Panelboards; Switchboards; High degree of current limitation for low peak let-thru current; CSA certified to standard C22.2 No. 248.12; Easy-to-read imprint label for quick recognition and replacement; Rejection style design prevents replacement by other fuse classes; Load centers; Bus duct; Fiberglass body provides dimensional stability in harsh industrial environments; Non-inductive loads; UL listed to standard 248-12 File E2137; Self-certified for DC per UL248