Browse Categories

Search in Category

Fuses

Filter Your Search

Hide Attribute Current
Hide Attribute Degree of protection (IP)
Hide Attribute Weight

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 244 of 1000 (10,000+ results)
25 URZ 17 P 125

25 URZ 17 P 125

Item #: Q097557

Supplier Part #: Q097557
Brand: Mersen

Extremely high breaking capacity fuses Protection of power semiconductors as per IEC standard 60269-1 and -4 250 V voltage rating as per IEC 33 gR class as per VDE 636-23 and IEC 60269.4 Design without indicator

UL Recognized

$412.10 /EA
NOT CURRENTLY IN STOCK
SI 00 DIN 80

SI 00 DIN 80

Item #: Q098040

Supplier Part #: Q098040
Brand: Mersen

Standard version SI fuse holders for stud-type fuses, for blade-type fuses SI 00 and SI 000, for bracket-type fuses SI DIN 80 and DIN 110 Mounting in one-pole fuse holder simplifies fuse replacement for installations connected with cables and bars For TTF stud-type fuses For blade and bracket-type fuses as per DIN 43653 standard Sizes: 000 - 00, 80 mm between axes Sizes: 0 - 1 - 2 - 3, 80 and 110 mm between axes For TTF version studs are delivered with the fuse holder Finger safe version available
$576.52 /EA
NOT CURRENTLY IN STOCK

CC6621 CP GRB 2760 315

Item #: Q098592

Supplier Part #: Q098592
Brand: Mersen

Mersen DC offers provide a very high performant protection for railway power and auxiliary circuits. Mersen DC Semiconductor fuse-links were developed to provide improved performance required by today's new DC equipment. These fuse-links are typically operated at more elevated temperature than other fuse type, have lower I²t to minimize damage to protected components on short circuits, lower watts loss and longer life.
$816.56 /EA
NOT CURRENTLY IN STOCK

H 2409P BCKUP VDE442-65/80

Item #: Q1000261

Supplier Part #: Q1000261
Brand: Mersen

Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor®-PD HV fuses are back-up fuses as defined in the standards IEC 60282-1 and VDE 0670 T402 and dedicated to protect transformers against effects of short-circuit currents. The VDE 0670 T402 defines fuses between 6.3A and 160A, for other ratings, thanks to consult Limitor®-P HV fuses range. To guarantee high quality, Mersen uses the best materials fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic.

VDE 0670 part 402; Low switching voltage; DIN 43625; New cap design for a better compatibility with all types of clips; Energy efficency; IEC 60282-1; medium striker 80N/30mm; High current limitation; Coordination with IEC 60787, IEC 62271-105, IEC/TR 62655; Quick breaking; Indoor and outdoor applications; VDE 0670 part 4; and easier assembly

$359.30 /EA
NOT CURRENTLY IN STOCK

6900 CP GR 1038 0002

Item #: Q1014567

Supplier Part #: Q1014567
Brand: Mersen

The 10x38 gR cylindrical is a fast acting, full range fuse used in the protection of inverters, UPS, variable speed drives and other discrete semiconductor devices.

Extremely fast acting; Excellent cycling capability; UL/CSA Recognized Component; AC: UL Guide No. E76491; Current limiting; gR Class according to IEC 60269-4 and VDE 636-23; IEC 60269-4 Compliance; Eliminate all overloads; Low I²t for improved semiconductor protection

$71.37 /EA
NOT CURRENTLY IN STOCK
DIII-RING-PASSEINSATZ 16A

DIII-RING-PASSEINSATZ 16A

Item #: Q200712

Supplier Part #: Q200712
Brand: Mersen

The D fuse-system is the first generation of the screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse-range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links gG is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents.

Clear indication of operation condition due to coloured indicator on top contact; Low power dissipation; Optimized size; Insulated body suitable for high mechanical and thermal impacts; Top and bottom contacts made of nickel plated copper alloy; Resistant to aging; Safe cut off short circuits and over currents due to special design of fuse element; Free of lead, cadmium, mercury, chrome 6 (rohs conformity)

Call
NOT CURRENTLY IN STOCK

500V CP 14X51 AM 40A S/I FS

Item #: Q200758

Supplier Part #: Q200758
Brand: Mersen

Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. Size 10x38 is also available with striker. All cylindrical fuse-links have ceramic bodies and silver-plated contacts. Cylindrical fuse-links "aM" are partial range fuses. They protect electrical devices in case of unacceptable high short-circuit against destruction due high current limiting and low thermal let-through values. They cut off currents more than 6.3xln until the maximum breaking capacity (rated breaking capacity). Cylindrical fuse-links "aM" are mainly used for the protection of installation switch gear in otor circuit currents. For classification of the cylindrical fuse-links the nominal current of the fuse-link can be selected respective to the nominal current of the motor. Our technology and process was designed to ensure highly reliable technical performance.

IEC 60269-1 & -2; Reduced size; Striker version available for remote indication of fuse operation; Safest and most reliable protection system; Approved by Lloyd’s Register of Shipping and Bureau Veritas

$19.40 /EA
NOT CURRENTLY IN STOCK

500V NH1 C/P gG 250A

Item #: Q201333

Supplier Part #: Q201333
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Lead free contact blades; IEC 60269-1 and -2; Dimensions according to DIN 43 620 Parts 1 to 4; VDE 0636 Part 201; 0% cadmium

$267.91 /EA
NOT CURRENTLY IN STOCK
DIII-RING-PASSEINSATZ 25A

DIII-RING-PASSEINSATZ 25A

Item #: Q201770

Supplier Part #: Q201770
Brand: Mersen

The D fuse-system is the first generation of the screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse-range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links gG is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents.

Safe cut off short circuits and over currents due to special design of fuse element; Optimized size; Clear indication of operation condition due to coloured indicator on top contact; Top and bottom contacts made of nickel plated copper alloy; Resistant to aging; Insulated body suitable for high mechanical and thermal impacts; Low power dissipation; Free of lead, cadmium, mercury, chrome 6 (rohs conformity)

Call
NOT CURRENTLY IN STOCK

NH 2 355A 500V GG

Item #: Q201862

Supplier Part #: Q201862
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

IEC 60269-1 and -2; Lead free contact blades; Dimensions according to DIN 43 620 parts 1 to 4; Non-isolated gripping lugs; Double indicator; VDE 0636 Part 201; 0% cadmium

$248.98 /EA
NOT CURRENTLY IN STOCK
  • « PREV
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • NEXT »