Search in Category
Filter Your Search
Shop by Category
Fuses
PWR DIS BLK AL INT 350A 2P 15
CSA Certified Class 6228 01; UL Listed to subject 1953, File E352417 unless noted otherwise
600V 30A CLASS J HS FUSE
UL listed to standard 248-8 File E2137; Excellent cycling ability for frequent starts/stops without nuisance opening; DC listed to UL 248; Optimized over-load capability for withstanding elevated levels of current during electronic motor controller starts; Solid state relays; Branch circuits; Drives; Phase controllers; Low I2t (low thermal energy); Control panels; CSA certified to standard C22.2 no. 248.8; Electronic motor controllers; Soft-starters
600V 35A CLASS J HS FUSE
Soft-starters; Control panels; Branch circuits; Electronic motor controllers; Excellent cycling ability for frequent starts/stops without nuisance opening; Phase controllers; Solid state relays; Optimized over-load capability for withstanding elevated levels of current during electronic motor controller starts; Low I2t (low thermal energy); UL listed to standard 248-8 File E2137; CSA certified to standard C22.2 no. 248.8; Drives; DC listed to UL 248
R FUSE BLOCK 600V 60A 2P BXR
UL recognized component guide IZLT2, file E52283; All fuse blocks meet the requirements of UL 4248; CSA certified class 6225, File 32169; UL listed, guide IZLT, File E52283
J TD FUSE 600V 45A AJT
Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Lighting, heating & general loads; Motor circuits; Bus duct; Fiberglass body provides dimensional stability in harsh industrial settings; CSA certified to standard C22.2 No. 248.8; DC tested to UL standard 248; Feeders; Control panels; Unique Class J dimensions prevent replacement errors; UL listed to standard 248-8 File E2137; Extremely current-limiting for low peak let-thru current; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Non-indicating or solid state SmartSpot visual blown fuse indicator; Mains; Most current-limiting UL class fuse; Circuit breaker back-up; UL listed; High-visibility orange label gives instant brand recognition; DC listed to UL standard 248; Metal-embossed date and catalog number for traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests; Load centers; Recommended for Arc Flash energy reduction; High-grade silica filler ensures fast arc quenching; Branch circuits; Transformers; IEC 60269-2-1; Time-delay for motor starting and transformer inrush
600V 8A CC TD FUSE(ATDR8)
Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High-grade silica filler ensures fast arc quenching and optimum current-limitation; Metal-embossed date and catalog number for traceability and lasting identification; Improved cycling ability for frequent motor starts/stops without nuisance fuse opening; Lighting, heating & general loads; DC listed to UL standard 248; Contactors; CSA certified to standard C22.2 No. 248.4; Time-delay for motor starting inrush currents without nuisance opening; High-visibility orange label ensures instant brand recognition, simplifies replacement; Highly current-limiting for low peak let-thru current; Fiberglass body provides dimensional stability in harsh industrial settings; UL listed to standard 248-4 File E2137; Small motors; Branch circuit protection
600V 15A CC FUSE
Control circuits; Branch circuit protection; Lighting; UL Listed to Standard 248-4 File E2137; CSA Certified to Standard C22.2 No. 248.4; Rejection-style design prevents replacement errors when used with recommended fuse blocks; Versatile design for individual component and branch circuit protection; General loads; DC listed to UL Standard 248
600V 7A CC FUSE
Versatile design for individual component and branch circuit protection; UL Listed to Standard 248-4 File E2137; CSA Certified to Standard C22.2 No. 248.4; Rejection-style design prevents replacement errors when used with recommended fuse blocks; Lighting; DC listed to UL Standard 248; General loads; Branch circuit protection; Control circuits
500V 2/10A TD MIDGET FUSE
UL listed to standard 248-14 File E33925; Supplemental protection of lighting, solenoid, motor and transformer circuits; 1 1/2” x 13/32” (10 mm x 38 mm) dimensions; CSA Certified to Standard C22.2 No. 248.14; Can be used with UltraSafeā¢ Fuse holders; Time-delay (12 seconds at 200 percent rating) for circuits with high inrush current; Numerous ratings for a wide variety of applications up to 500VAC
500V 30A TD MIDGET FUSE
Supplemental protection of lighting, solenoid, motor and transformer circuits; Can be used with UltraSafeā¢ Fuse holders; UL listed to standard 248-14 File E33925; CSA Certified to Standard C22.2 No. 248.14; 1 1/2” x 13/32” (10 mm x 38 mm) dimensions; Numerous ratings for a wide variety of applications up to 500VAC; Time-delay (12 seconds at 200 percent rating) for circuits with high inrush current