CC TD FUSE 600V 1/4A ATQR
High-grade silica filler ensures fast arc quenching and high current limitation; Highly current-limiting for low peak let-thru current; Control transformers; Fiberglass body provides dimensional stability in harsh industrial settings; Time-delay for control transformer inrush loads without nuisance opening; DC listed to UL standard 248; Metal-embossed date and catalog number for traceability and lasting identification; Solenoids; High visibility orange label ensures instant brand recognition, and simplifies replacement; CSA certified to standard C22.2 No. 248.4; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); UL listed to standard 248-4 File E2137; Inductive loads; Lighting, heating & general-purpose loads
PWR DIS BLK AL MINI 175A 2P S
UL Listed to subject 1953, File E352417 unless noted otherwise; CSA Certified Class 6228 01
30A J 2P ULTRASAFE W/IND
Compact footprint; DIN-rail mount; UL Listed, guide IZLT File E52283; Finger-safe IP20 protection; Optional indicator lights; IEC certified 60269-1, 60947-3; CSA Certified C22.2, class 6225 01, File 32169; Quick, easy fuse change
SC FUSE 700V 50A QS 14X51
Superior cycling ability for longer life on difficult cyclic loading applications; Ferrule mount for design versatility; International 14 × 51mm (2 In x 9/16 In) and 22 × 58mm (2-1/4 In x 13/16 In) sizes for worldwide acceptance; Very low I2t for improved semiconductor protection; 700VDC rated for dc protection of equipment with L/R <= 10ms/c; 690V IEC rated, tested at 760VAC; can be used up to 750VAC in U.S.
SC FUSE 700V 50A QS BLADE
Ultra compact sizes allow down-sizing of existing equipment; 700V AC/DC rating gives greater design versatility; DC: tested to UL standard 198L parameters (35-800A); Low watts loss for cooler operation; UL recognized component, AC/DC UL file E60314; AC: guide no. JFHR2; CSA certified File LR 12636; Very Low I2t for improved protection of equipment; Superior cycling ability for long, reliable life on high cyclic loading
J TD FUSE 600V 20A AJT
Motor circuits; 300kA interrupting rating – self-certified, UL witnessed tests; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; DC tested to UL standard 248; Metal-embossed date and catalog number for traceability and lasting identification; Bus duct; Most current-limiting UL class fuse; High-visibility orange label gives instant brand recognition; IEC 60269-2-1; Recommended for Arc Flash energy reduction; Lighting, heating & general loads; Circuit breaker back-up; DC listed to UL standard 248; Transformers; Branch circuits; Time-delay for motor starting and transformer inrush; Unique Class J dimensions prevent replacement errors; UL listed to standard 248-8 File E2137; Fiberglass body provides dimensional stability in harsh industrial settings; Feeders; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Non-indicating or solid state SmartSpot visual blown fuse indicator; Mains; Control panels; CSA certified to standard C22.2 No. 248.8; Extremely current-limiting for low peak let-thru current; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; UL listed; High-grade silica filler ensures fast arc quenching; Load centers
CC TD FUSE 600V 1A ATDR
High-visibility orange label ensures instant brand recognition, simplifies replacement; Lighting, heating & general loads; CSA certified to standard C22.2 No. 248.4; Improved cycling ability for frequent motor starts/stops without nuisance fuse opening; Contactors; Metal-embossed date and catalog number for traceability and lasting identification; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Fiberglass body provides dimensional stability in harsh industrial settings; High-grade silica filler ensures fast arc quenching and optimum current-limitation; Branch circuit protection; DC listed to UL standard 248; UL listed to standard 248-4 File E2137; Time-delay for motor starting inrush currents without nuisance opening; Highly current-limiting for low peak let-thru current; Small motors
500V 2A TD MIDGET FUSE
Can be used with UltraSafeā¢ Fuse holders; 1 1/2” x 13/32” (10 mm x 38 mm) dimensions; CSA Certified to Standard C22.2 No. 248.14; Numerous ratings for a wide variety of applications up to 500VAC; Supplemental protection of lighting, solenoid, motor and transformer circuits; UL listed to standard 248-14 File E33925; Time-delay (12 seconds at 200 percent rating) for circuits with high inrush current
CC TD FUSE 600V 1/2A ATQR
Inductive loads; Solenoids; Metal-embossed date and catalog number for traceability and lasting identification; CSA certified to standard C22.2 No. 248.4; Control transformers; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Highly current-limiting for low peak let-thru current; High-grade silica filler ensures fast arc quenching and high current limitation; UL listed to standard 248-4 File E2137; Time-delay for control transformer inrush loads without nuisance opening; DC listed to UL standard 248; Lighting, heating & general-purpose loads; High visibility orange label ensures instant brand recognition, and simplifies replacement; Fiberglass body provides dimensional stability in harsh industrial settings