Search in Category
Filter Your Search
Shop by Category
Fuses
5X20MM FUSE 250V 1/4A GDG
1/16A through 10A, 250VAC, UL & CSA Recognized; Glass body; Time-delay; 1/16A through 6-3/10A, 250VAC, VDE Approved; IEC 127-2 Standard Sheet 3; 1/16A through 6-3/10A, 250VAC, SEMKO Approved; 5 mm x 20 mm
5X20MM FUSE 250V 2A GDG
1/16A through 10A, 250VAC, UL & CSA Recognized; Time-delay; Glass body; 1/16A through 6-3/10A, 250VAC, SEMKO Approved; 1/16A through 6-3/10A, 250VAC, VDE Approved; IEC 127-2 Standard Sheet 3; 5 mm x 20 mm
5X20MM FUSE 250V 3A GGM
10A and 15A, 250VAC, UL Recognized; 1/16A through 3A, 250VAC, UL Listed and CSA Certified; Glass body; 5 mm x 20 mm; 4A through 8A, 125VAC, UL Listed and CSA Certified; Fast-acting
PWR DIS BLK AL INT 310A AD 4
UL Listed to subject 1953, File E352417 unless noted otherwise; CSA Certified Class 6228 01
250V 30A 1 1/2x13/32 MID TD
UL listed to standard 248-14 File E33925; 1 1/2” x 13/32” (10mm x 38mm) dimensions; Small transformers; Small motors; CSA Certified to Standard C22.2 No. 248.14; Numerous ratings for a wide variety of applications; Control circuits; Can be used with UltraSafeTM fuse holders; Lighting circuits; 250VAC rating in all sizes up to 30A; Time-delay for circuits with high inrush currrent
SC FUSE 700V 25A QS 22X58
700VDC rated for dc protection of equipment with L/R <= 10ms/c; Superior cycling ability for longer life on difficult cyclic loading applications; International 14 × 51mm (2 In x 9/16 In) and 22 × 58mm (2-1/4 In x 13/16 In) sizes for worldwide acceptance; Very low I2t for improved semiconductor protection; 690V IEC rated, tested at 760VAC; can be used up to 750VAC in U.S.; Ferrule mount for design versatility
FUSE 600V 2A CLASS CC
Highly current-limiting for low peak let-thru current; DC listed to UL standard 248; Metal-embossed date and catalog number for traceability and lasting identification; Improved cycling ability for frequent motor starts/stops without nuisance fuse opening; High-visibility orange label ensures instant brand recognition, simplifies replacement; High-grade silica filler ensures fast arc quenching and optimum current-limitation; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); UL listed to standard 248-4 File E2137; Small motors; Lighting, heating & general loads; CSA certified to standard C22.2 No. 248.4; Contactors; Fiberglass body provides dimensional stability in harsh industrial settings; Branch circuit protection; Time-delay for motor starting inrush currents without nuisance opening
500V 10A TD MIDGET FUSE
1 1/2” x 13/32” (10 mm x 38 mm) dimensions; Time-delay (12 seconds at 200 percent rating) for circuits with high inrush current; CSA Certified to Standard C22.2 No. 248.14; Supplemental protection of lighting, solenoid, motor and transformer circuits; UL listed to standard 248-14 File E33925; Numerous ratings for a wide variety of applications up to 500VAC; Can be used with UltraSafeā¢ Fuse holders
CC TD FUSE 600V 20A ATQR
Inductive loads; Fiberglass body provides dimensional stability in harsh industrial settings; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High-grade silica filler ensures fast arc quenching and high current limitation; Control transformers; High visibility orange label ensures instant brand recognition, and simplifies replacement; Time-delay for control transformer inrush loads without nuisance opening; Solenoids; Metal-embossed date and catalog number for traceability and lasting identification; DC listed to UL standard 248; Lighting, heating & general-purpose loads; CSA certified to standard C22.2 No. 248.4; UL listed to standard 248-4 File E2137; Highly current-limiting for low peak let-thru current
PWR DIS BLK AL INT 350A 1P 15
CSA Certified Class 6228 01; UL Listed to subject 1953, File E352417 unless noted otherwise