Search in Category
Filter Your Search
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
![Hide Attribute](/images/misc/collapsed.gif)
Shop by Category
Fuses
600V 30A 2P CC ULTSFE
ATM, DCT, ATMR recommended for DC applications; Quick, tool-free, easy fuse change outs; Optional visual blown fuse Indicator lights; CSA Certified C22.2; UL Listed to standard 4248-18 (photovoltaic), File E347822; IEC 60269-2-1 and 60947-3 Compliant (USM only); UL Listed to Standard 4248- 4 (class CC) and 4248-1 (midget), File E52283; IP20 Finger-Safe (touch safe); DIN-rail mounting; Compact footprint
600V 30A 3P CC ULTSFE
DIN-rail mounting; CSA Certified C22.2; IP20 Finger-Safe (touch safe); ATM, DCT, ATMR recommended for DC applications; UL Listed to Standard 4248- 4 (class CC) and 4248-1 (midget), File E52283; Compact footprint; UL Listed to standard 4248-18 (photovoltaic), File E347822; IEC 60269-2-1 and 60947-3 Compliant (USM only); Optional visual blown fuse Indicator lights; Quick, tool-free, easy fuse change outs
FUSE HOLDER 1-P 32A 600V CLASS CC F
SAFETY COVER PULLER LP
5X20MM FUSE 250V 1A GGM
10A and 15A, 250VAC, UL Recognized; Fast-acting; Glass body; 1/16A through 3A, 250VAC, UL Listed and CSA Certified; 4A through 8A, 125VAC, UL Listed and CSA Certified; 5 mm x 20 mm
CC TD FUSE 600V 12A ATDR
![https://media.distributordatasolutions.com/mersen/2021q1/documents/22d037a2b3fd020be01a4f5f0a2f2636518fa377.pdf https://media.distributordatasolutions.com/mersen/2021q1/documents/22d037a2b3fd020be01a4f5f0a2f2636518fa377.pdf](/images/misc/wa_pdficon.png)
![https://media.distributordatasolutions.com/mersen/2021q1/documents/4058bb4dc548d69513f7d8fc7060f268d0ced1e8.pdf https://media.distributordatasolutions.com/mersen/2021q1/documents/4058bb4dc548d69513f7d8fc7060f268d0ced1e8.pdf](/images/misc/wa_pdficon.png)
![https://media.distributordatasolutions.com/mersen/2021q1/documents/7be85c101741784fa9cc0422deee51d32c06d69d.pdf https://media.distributordatasolutions.com/mersen/2021q1/documents/7be85c101741784fa9cc0422deee51d32c06d69d.pdf](/images/misc/wa_pdficon.png)
Fiberglass body provides dimensional stability in harsh industrial settings; Lighting, heating & general loads; Improved cycling ability for frequent motor starts/stops without nuisance fuse opening; Highly current-limiting for low peak let-thru current; High-grade silica filler ensures fast arc quenching and optimum current-limitation; UL listed to standard 248-4 File E2137; DC listed to UL standard 248; Time-delay for motor starting inrush currents without nuisance opening; CSA certified to standard C22.2 No. 248.4; High-visibility orange label ensures instant brand recognition, simplifies replacement; Small motors; Branch circuit protection; Contactors; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Metal-embossed date and catalog number for traceability and lasting identification
600V 30A SP CC ULTSFE W/IND
UL Listed to Standard 4248- 4 (class CC) and 4248-1 (midget), File E52283; UL Listed to standard 4248-18 (photovoltaic), File E347822; IEC 60269-2-1 and 60947-3 Compliant (USM only); DIN-rail mounting; ATM, DCT, ATMR recommended for DC applications; IP20 Finger-Safe (touch safe); Compact footprint; Optional visual blown fuse Indicator lights; CSA Certified C22.2; Quick, tool-free, easy fuse change outs
FUSE HOLDER 3-P 32A 600V CLASS CC FUSE
CC TD FUSE 600V 2A ATQR
![https://media.distributordatasolutions.com/mersen/2021q1/documents/222df8314d28c27e6deebfcdea658e6085079ff2.pdf https://media.distributordatasolutions.com/mersen/2021q1/documents/222df8314d28c27e6deebfcdea658e6085079ff2.pdf](/images/misc/wa_pdficon.png)
![https://media.distributordatasolutions.com/mersen/2021q1/documents/45f3e2f9e5c622520927eac779a0544c26242531.pdf https://media.distributordatasolutions.com/mersen/2021q1/documents/45f3e2f9e5c622520927eac779a0544c26242531.pdf](/images/misc/wa_pdficon.png)
![https://media.distributordatasolutions.com/mersen/2021q1/documents/842a8b234a1f7e6fca063edb2ec4f74051760b11.pdf https://media.distributordatasolutions.com/mersen/2021q1/documents/842a8b234a1f7e6fca063edb2ec4f74051760b11.pdf](/images/misc/wa_pdficon.png)
CSA certified to standard C22.2 No. 248.4; Fiberglass body provides dimensional stability in harsh industrial settings; Inductive loads; High-grade silica filler ensures fast arc quenching and high current limitation; Highly current-limiting for low peak let-thru current; UL listed to standard 248-4 File E2137; Lighting, heating & general-purpose loads; Time-delay for control transformer inrush loads without nuisance opening; Metal-embossed date and catalog number for traceability and lasting identification; Control transformers; Solenoids; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); DC listed to UL standard 248; High visibility orange label ensures instant brand recognition, and simplifies replacement
MOV FUSE 600V SR40KA-2
ANSI/UL 248 Special Purpose MOV Fuse, File E60314; VSP fuses rated 600VAC, 200kA I.R.; Surge ratings of 5-100kA 8/20 µSec capacity; Various mounting configurations ferrules, blade, bolt-in, PC board mount
![Question Mark Box](/images/Misc/question_mark_box.gif)