SAFETY COVER FOR MINI MPDB
CSA Certified Class 6228 01; UL Listed to subject 1953, File E352417 unless noted otherwise
MOV FUSE 600V SR40KA-2
ANSI/UL 248 Special Purpose MOV Fuse, File E60314; VSP fuses rated 600VAC, 200kA I.R.; Surge ratings of 5-100kA 8/20 µSec capacity; Various mounting configurations ferrules, blade, bolt-in, PC board mount
CC TD FUSE 600V 7A ATQR
CSA certified to standard C22.2 No. 248.4; Highly current-limiting for low peak let-thru current; Metal-embossed date and catalog number for traceability and lasting identification; Solenoids; Time-delay for control transformer inrush loads without nuisance opening; High-grade silica filler ensures fast arc quenching and high current limitation; Lighting, heating & general-purpose loads; High visibility orange label ensures instant brand recognition, and simplifies replacement; Inductive loads; UL listed to standard 248-4 File E2137; Control transformers; Fiberglass body provides dimensional stability in harsh industrial settings; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); DC listed to UL standard 248
600V 30A SP CC ULTSFE W/IND
UL Listed to Standard 4248- 4 (class CC) and 4248-1 (midget), File E52283; UL Listed to standard 4248-18 (photovoltaic), File E347822; IEC 60269-2-1 and 60947-3 Compliant (USM only); DIN-rail mounting; ATM, DCT, ATMR recommended for DC applications; IP20 Finger-Safe (touch safe); Compact footprint; Optional visual blown fuse Indicator lights; CSA Certified C22.2; Quick, tool-free, easy fuse change outs
600V 8A CC TD FUSE
High-grade silica filler ensures fast arc quenching and high current limitation; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High visibility orange label ensures instant brand recognition, and simplifies replacement; DC listed to UL standard 248; UL listed to standard 248-4 File E2137; Control transformers; Time-delay for control transformer inrush loads without nuisance opening; CSA certified to standard C22.2 No. 248.4; Inductive loads; Highly current-limiting for low peak let-thru current; Metal-embossed date and catalog number for traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings; Solenoids; Lighting, heating & general-purpose loads
CC TD FUSE 600V 15A ATQR
Fiberglass body provides dimensional stability in harsh industrial settings; Highly current-limiting for low peak let-thru current; Inductive loads; High visibility orange label ensures instant brand recognition, and simplifies replacement; Control transformers; UL listed to standard 248-4 File E2137; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); CSA certified to standard C22.2 No. 248.4; Metal-embossed date and catalog number for traceability and lasting identification; Solenoids; Time-delay for control transformer inrush loads without nuisance opening; High-grade silica filler ensures fast arc quenching and high current limitation; Lighting, heating & general-purpose loads; DC listed to UL standard 248
1000VDC/1A MIDGET FUSE
UL Recognized component File E60314; 1 1/2” x 13/32” (10 mm x 38 mm) dimensions; Semiconductor protection; DC traction equipment; Low minimum breaking capacity (MBC); Multi-meters; Ferrule mount 1 to 30A for design versatility; Photovoltaic systems; Compact size: 10 × 38 mm (13/32” x 1-1/2”) size internationally accepted; Can be used with UltraSafeTM fuse holders USM series
PWR DIS BLK AL INT 175A 1P 12
CSA Certified Class 6228 01; UL Listed to subject 1953, File E352417 unless noted otherwise
PWR DIS BLK AL LG 840A 2P 2
CSA Certified Class 6228 01; UL Listed to subject 1953, File E352417 unless noted otherwise
J TD FUSE 600V 50A AJT
Transformers; CSA certified to standard C22.2 No. 248.8; DC listed to UL standard 248; DC tested to UL standard 248; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Most current-limiting UL class fuse; Lighting, heating & general loads; 300kA interrupting rating – self-certified, UL witnessed tests; Unique Class J dimensions prevent replacement errors; Fiberglass body provides dimensional stability in harsh industrial settings; Non-indicating or solid state SmartSpot visual blown fuse indicator; UL listed; Load centers; UL listed to standard 248-8 File E2137; Time-delay for motor starting and transformer inrush; Control panels; Bus duct; High-grade silica filler ensures fast arc quenching; Circuit breaker back-up; IEC 60269-2-1; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Motor circuits; Feeders; Mains; Branch circuits; Extremely current-limiting for low peak let-thru current; Recommended for Arc Flash energy reduction; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; High-visibility orange label gives instant brand recognition; Metal-embossed date and catalog number for traceability and lasting identification